online ups (HP900C-RM(6~10kVA))
Product Details:
| Phase | Single Phase |
|---|---|
| Type | On-line |
| Application | Telecommunications |
| Place of Origin | Shandong, China |
| Brand Name | KSTAR |
| Model Number | HP900C-RM(6~10kVA) |
Payment & Shipping Terms:
| Delivery Time: | 30 days |
|---|---|
| Payment Terms: | L/C,T/T |
Detailed Product Description
On-line ups
Features :
1. High frequency and double conversion on-line technology
2. Fully digitized microprocessor control
3. Wide input voltage range
4. LCD display
5. Cold start
6. Parallel capacity
7. Advanced battery management
8. Automatic battery charge in UPS off mode
9. Lightning and surge protection
10. Short circuit and overload protection
11. Fan speed auto control when loads varies
12. Optional extension battery pack
13. EMI/RFI noise filter
14. Smart RS232 communication with monitoring software
15. Optional SNMP Card slot
| Model | HP960C | HP960C-RM | HP9100C | HP9100C-RM | |||||
| Capacity | 6KVA/4.2KW | 10KVA/7KW | |||||||
| Input | Voltage Range | 176±5VAC~276±5VAC | |||||||
| Frequency Range | 46~54Hz±0.5Hz or | ||||||||
| 56~64Hz±0.5Hz auto sensing | |||||||||
| Phase | Single phase | ||||||||
| Power Factor | ≥0.98 | ||||||||
| Output | Voltage Range | 220Vac±1% | |||||||
| Phase | Single phase | ||||||||
| Frequency Range | 50Hz/60Hz±0.2%(battery mode) | ||||||||
| THD (linear load) | <2% | ||||||||
| THD (non-linear load) | < 6% | ||||||||
| Overload Capability | 105%~130%, 10min turn to bypass mode;>130% 1s turn to bypass mode | ||||||||
| Crest Factor | 3:1(max) | ||||||||
| Short Circuit Protection | 5 cycles turn off inverter, no transfer to bypass, provide alarm (AC mode) | ||||||||
| 5 cycles turn off inverter, provide alarm (battery mode) | |||||||||
| input fuse blown or breaker action (bypass mode) | |||||||||
| Waveform | pure sine wave | ||||||||
| Transfer Time Between AC Mode and Battery Mode | 0ms | ||||||||
| Transfer Time Between AC Mode and Bypass Mode | 0ms | ||||||||
| Efficiency | ≥88% | ||||||||
| Battery | Model | 12V sealed lead acid maintenance free | |||||||
| DC Voltage | 240VDC | ||||||||
| Configuration | 20×12V/7AH | ||||||||
| Backup Timehalf load | 20min | N/A | 13min | N/A | |||||
| Backup Timefull load | 7min | N/A | 5min | N/A | |||||
| Charge Current(standard unit) | 1A | ||||||||
| Charge Current(long time unit) | 5A | ||||||||
| Recharge Time | 90% capacity after 8 hrs charging | ||||||||
| Communication Interface | RS232 ; SNMP (optional) | ||||||||
| Parallel port | Parallel availability for redundancy and load sharing up to three units | ||||||||
| LCD Indication | 1, Input voltage/frequency, battery voltage, output voltage/frequency, load watt/VA value and percent, inverter temperature | ||||||||
| 2, Operation mode such as on line, on batt, or or bypass | |||||||||
| LED Indication | 1, Green LED for normal operation, | ||||||||
| 2, Yellow LED for warning condition | |||||||||
| 3, Red LED for abnormal operation | |||||||||
| Noise Level | <55dB | ||||||||
| Environment | Temperature | 0~40 | |||||||
| Humidity | 0%~95% (non-condensing) | ||||||||
| Altitude | <1500m | ||||||||
| Storage Temperature | 0~40 | ||||||||
| Other | Standard Unit Net/Gross Weight | 89/104kg | N/A | 92/107kg | N/A | ||||
| Long Time Unit Net/Gross Weight | 33/43Kg | 22/25Kg | 36/46Kg | 22/25Kg | |||||
| Dimension (W×D×H)mm | 270×570×720 | 440×656×176 | 270×570×720 | 440×656×176 | |||||
| Packing (W×D×H)mm | 370×670×940 | 580×790×336 | 370×670×940 | 580×790×336 | |||||
online ups (HP900C-RM(6~10kVA))
Product Showcase[30]
Products
- Online UPS [19]
- offline UPS [2]
- DC UPS [1]
- Line interactive UPS [2]
- Inverter [4]
- Sealed Lead Acid Battery [39]
Company Info
Shenzhen KSTAR Science and Technology Co., Ltd.
[China]
[Verified Member]
City: Shenzhen
Province/State: Guangdong
Country/Region : China
Business Type:Manufacturer
Online Postings: Products